It shall consist of top and bottom reinforcement each with layer of bars placed parallel to the sides of the slab and extending from the edges a minimum distance of one fifth of the shorter span.
Rcc sloped roof reinforcement detail.
The overhanging distance of the roof is equal to 60cm.
The reinforcement detail of a sloped concrete roof that is supported by a beam of cross section.
A stiff concrete mix specified at 3000 psi is pumped into place as workers advance up the slope to vi brate and finish the concrete to the desired thickness.
Cross section detail of a reinforced concrete sloped inclined roof slab overhang cantilever detail supported from a concrete beam.
Cantilever longitudinal and transverse reinforcement bars.
Sloped roof reinforcement details.
The thickness of the concrete roof used in 200mm.
Torsion reinforcement shall be provided at any corner where the slab is simply supported on both edges meeting at that corner and is prevented from lifting unless the consequences of cracking are negligible.
Minimum and max reinforcement in beams slabs and columns as per codal provisions should be followed.
Based on the boundary condition you can determine the axial thrust and the bending moment.
Tips for laying rcc slab roof on 12 09 2014 9091 view s 3 comment s rcc slab laying is one of major step in any type of construction so it is mandatory to know all the points related to laying rcc slab.
A sloped concrete roof is much more complicated king confirms.
Here is a detailed article with all the information regarding procedure of rcc slab roof laying.
Tips for laying rcc slab roof on 12 09 2014 9091 view s 3 comment s rcc slab laying is one of major step in any type of construction so it is mandatory to know all the points related to laying rcc slab.
250 x 500mm is given below.
Posted july 20th 2011 by selvam vb.
Reinforcement projecting from the concrete or masonry walls is bent to the slope of the roof and lapped with the roof s rebar to pro vide secure anchorage.
The slab is provided with bottom longitudinal reinforcement and top reinforcement as shown in figure 1 above.
It is better to provide a max spacing of 200mm 8 for main bars and 250mm 10 in order to control the crack width and spacing.
If the problem is statically determinate the equilibrium equations would.
Dear all can anyone please help me how to fix the reinforcement in the sloped roof both one side and two sides as per the i s codes and if any reference book having full detailing about the how to.
Spalling of concrete how to fix spalling in concrete.
Here is a detailed article with all the information regarding procedure of rcc slab roof laying.